Superheat & Subcooling Calculator

Quick refrigerant charge check

Free tool for field decisions

Why this tool matters

Solve the calculation or lookup now, then use the demo to see how the answer can stay visible on the morning operating board.

Next best step

Use the result in the field, then see the interactive demo when you want the answer to stay visible after this visit.

Use PT chart to convert suction pressure to saturation temp

Superheat Targets

Fixed Orifice: 8-12°F

TXV System: 5-10°F

Low (<5°F): Overcharge or TXV flooding

High (>15°F): Undercharge or restriction

Subcooling Targets

Target Range: 10-15°F

Most Systems: 12°F ideal

Low (<8°F): Undercharge

High (>18°F): Overcharge or restriction

Quick Guide

Superheat = Suction Line Temp - Saturation Temp (from suction pressure)

Subcooling = Saturation Temp (from liquid pressure) - Liquid Line Temp

Pro Tip: Always check both superheat AND subcooling for accurate diagnosis